File:Real-time MRI of a human heart (2-chamber view).ogv

Real-time_MRI_of_a_human_heart_(2-chamber_view).ogv(Ogg Theora video file, length 7.8 s, 463 × 463 pixels, 537 kbps, file size: 513 KB)


Wikimedia Commons Logo This free media file is from Wikimedia Commons. Its description page is included below.
Description
English: Real-time MRI of a human heart (2-chamber view) at 2.0 mm spatial resolution and 22 ms temporal resolution. The T1-weighted images were acquired with an RF-spoiled radial FLASH CMR sequence (TR/TE = 2.0/1.3 ms, flip angle 8°, 11 spokes) at 2.0 mm resolution, 8 mm section thickness, and 22 ms acquisition time without ECG or respiratory gating. Image reconstruction was achieved by regularized nonlinear inversion. (See: doi:10.1186/1532-429X-12-39 http://www.jcmr-online.com/content/12/1/39)
Date
Source

http://www.jcmr-online.com/content/12/1/39

doi:10.1186/1532-429X-12-39
Author Shuo Zhang, Martin Uecker, Dirk Voit, Klaus-Dietmar Merboldt, Jens Frahm
Permission
(Reusing this file)
w:en:Creative Commons
attribution
This file is licensed under the Creative Commons Attribution 2.0 Generic license.
You are free:
  • to share – to copy, distribute and transmit the work
  • to remix – to adapt the work
Under the following conditions:
  • attribution – You must give appropriate credit, provide a link to the license, and indicate if changes were made. You may do so in any reasonable manner, but not in any way that suggests the licensor endorses you or your use.

Contact:

Biomedizinische NMR Forschungs GmbH am Max-Planck-Institut für biophysikalische Chemie Am Fassberg 11 37077 Göttingen

Literature:

Martin Uecker, Shuo Zhang, Dirk Voit, Alexander Karaus, Klaus-Dietmar Merboldt, and Jens Frahm, Real-time magnetic resonance imaging at a resolution of 20 ms, NMR in Biomedicine 23: 986–994 (2010) DOI:10.1002/nbm.1585

Captions

Add a one-line explanation of what this file represents

Items portrayed in this file

depicts

8 July 2010

File history

Click on a date/time to view the file as it appeared at that time.

Date/TimeThumbnailDimensionsUserComment
current11:28, 29 May 20117.8 s, 463 × 463 (513 KB)Marmau{{Information |Description ={{en|1=Real-time MRI of a human heart (2-chamber view) at 2.0 mm spatial resolution and 22 ms temporal resolution. The T1-weighted images were acquired with an RF-spoiled radial FLASH CMR sequence (TR/TE = 2.0/1.3 ms, flip a

There are no pages that use this file.

Global file usage

The following other wikis use this file:

Metadata